Fiber cables builtto your exact spec.
Choose the fiber grade, connectors, polarity, jacket and length down to the centimeter. We build it, test every connector, and ship it with its own test report.
Stop paying for cable you coil in the rack.
Catalog cables come in 1, 2, 3 and 5 meter lengths with a handful of connector pairs. Real racks don't. Here's a run that needs 3.4 meters.
Off the shelf
Nearest stock length is 5 m, with LC on both ends.
- 1.6 m of slack looped behind the patch panel, blocking airflow
- A 12-fiber trunk becomes 12 separate duplex cords and a cassette
- Extra mated pairs add insertion loss to your link budget
Configured with FiberHalo
Built to 3.40 m with the connectors each end actually plugs into.
- You pay per meter for exactly the length you enter
- One MPO-to-LC split cable replaces the cords and the cassette
- Clean runs, fewer connection points, a rack you can still work in
From spec to rack in four steps.
Configure
Pick the fiber, connectors, polarity, jacket, length and labels. The price updates as you go.
Build and polish
Each assembly is terminated and machine-polished to your chosen UPC or APC end face.
Test every connector
Insertion loss, return loss, end-face inspection and polarity, on every fiber of every cable.
Ship with the report
Each cable is serialized and labeled, with its test results packed alongside it.
Tested one cable at a time.
We don't sample a batch and hope. Every fiber in every assembly is measured before it leaves us.
Optical performance
Insertion loss and return loss measured per fiber at 1310/1550 nm for single mode and 850/1300 nm for multi mode.
End-face inspection
Every ferrule is checked under magnification against IEC 61300-3-35 for scratches, pits and contamination.
Geometry and polish
Interferometer checks of radius of curvature, apex offset and fiber height keep mated connectors in physical contact.
Polarity and traceability
MPO polarity is verified end to end, and each cable carries a serial number that matches its test report.
| Connector | Insertion loss | Return loss |
|---|---|---|
| LC, SC, FC, E2000, single mode UPC | ≤ 0.25 dB | ≥ 50 dB |
| LC, SC, FC, E2000, single mode APC | ≤ 0.25 dB | ≥ 60 dB |
| LC, SC, ST, FC, E2000, multi mode | ≤ 0.30 dB | ≥ 30 dB |
| MPO/APC, single mode | ≤ 0.35 dB | ≥ 60 dB |
| MPO/UPC, single mode | ≤ 0.35 dB | ≥ 50 dB |
| MPO/UPC, multi mode | ≤ 0.35 dB | ≥ 25 dB |
Maximum values per mated connector pair. Anything outside these limits is reworked or scrapped, never shipped.
Made for the rooms where links can't fail.
Our core work is data center cabling, and the same build standard goes into every other application we serve.
Data centers
Spine-leaf fabrics, high-density MPO trunks and breakouts that take 40G, 100G and 400G ports down to individual LC connections.
Typical build: 12F MPO/UPC to 6 duplex LC, OM4
Telecom and 5G
Low-reflection APC assemblies for central offices, fronthaul and outside-plant cabinets where return loss matters.
Typical build: simplex SC/APC to LC, single mode
Enterprise and campus
Backbone and horizontal links between telecom rooms, cut to the distances your floor plan actually has.
Typical build: duplex LC to SC, multi mode
Broadcast and AV
Rugged patch cords for studios, OB vans and live events carrying uncompressed video over fiber.
Typical build: duplex LC, single mode
Labs and test benches
Reference-grade jumpers with tight loss limits for transceiver validation and equipment qualification.
Typical build: simplex LC/UPC, single mode
Something else?
If your build isn't covered by the configurator, send us the spec and we'll quote it within one working day.
Questions buyers ask.
Is there a minimum order quantity?
No. You can order a single cable. Volume pricing starts automatically at 10 pieces of the same configuration.
What's the difference between a simple and a split cable?
A simple cable has the same fiber count on both ends, like an MPO-to-MPO trunk or a duplex LC-to-SC cord. A split cable (also called a breakout or fanout) starts as one multi-fiber connector and splits into several legs, like one 12-fiber MPO into 12 LC connectors.
Which polarity and pin gender do I need?
For duplex cords, A-to-B is the standard. For MPO trunks, match the polarity method (Type A, B or C) used by your cassettes and transceivers. MPO equipment ports and cassettes usually have pins (male), so trunks between them are typically female on both ends. If you're unsure, send us the part numbers on each end and we'll confirm.
What do LSZH, OFNR and OFNP mean?
They're fire ratings for the cable jacket. LSZH gives off low smoke and no halogens, and is standard for data centers and most indoor use. OFNR (riser) is rated for vertical runs between floors. OFNP (plenum) is the highest rating, required in air-handling spaces such as raised floors and drop ceilings in many buildings.
How long does a custom build take?
Most configurations ship within 5 working days. Large volume orders get a confirmed date when you place the order.
Should I choose single mode or multi mode?
Match whatever your transceivers and existing plant use. Single mode is the choice for long runs and telecom; multi mode is common for short data center links. If you're unsure, check the transceiver label or send us the part number.
Can I get a test report for each cable?
Yes, and it's included at no charge. Every cable ships serialized with insertion loss, return loss and end-face results for each fiber.
Know your spec? Price it in under a minute.
Configure a cableConfigure your cable
Work through each step. Options that don't fit your earlier choices are greyed out, so anything you can select can be built. The drawing and price on the right update as you go.
Mode and fiber grade
Fiber grade
Cable type
Number of fibers
Connectors
End A
Number of splits
How many separate legs the cable fans out into on side B. Each leg gets its own connector.
End B
Polarity
Cable construction
Jacket rating
Cable diameter
LC duplex boot style
Uniboot carries both fibers in one round cable and one boot, which saves space in dense panels.
Armor
Jacket color
Length
Breakout length
How far the individual legs run past the fanout. Included in the overall length above.
Labels and testing
Labels
Pulling eye
A protective sleeve over the MPO end so trunks can be pulled through trays and conduit without damage.
Test report
Insertion loss, return loss and end-face inspection results are always included, free.
Quantity
Volume pricing: 5% off at 10+, 10% off at 50+, 15% off at 100+